Addressing of Delta PLC DVP SS/ES/EX

Addressing of Delta PLC DVP SS/ES/EX

Digital Input
X0-X177 Octal System i.e. (X0 To X7,X20 to X27 )
Digital Output
Y0-Y177 Octal System i.e. (Y0 To Y7,Y20 to Y27 )
Analog Input
Need To Read Control Register using “From” Instruction
Analog Output
Need To Write Control Register using “To” Instruction
Timers
T0 to T127(T0 to T126 =TB 100ms Default)
For Timers : Time Delay = Time Base *
Preset
Time Done Bit : Tx
Where X is address of Timer used.
Addressing of Delta PLC DVP SS/ES/EX
Addressing of Delta PLC DVP SS/ES/EX

 

Counters
General C0 to C111, C112 to C127 Retentive
For Counter:  Preset is number of Counts.
Counter Done Bit : Cx
Present value of Counter :Cx
Where X is address of counter used.
Addressing of Delta PLC DVP SS/ES/EX
Addressing of Delta PLC DVP SS/ES/EX

 

Integer
D0 to D599(D408 to D599 Retentive)
 Auxiliary Relay
M0 to M999 (M512 to M767 Retentive)
Programming Software : WPLSoft2.20
Driver For Programming:  Modbus Serial
Driver For SCADA Communication : Modbus