PLC Program for Traffic Light Control

PLC Program
for Traffic Light Control

 

Control Purpose:
  • Enabling the traffic lights to work by Start button X0 and to stop by Stop button X1.
  • Setting the time of red light in East-West direction as 60 sec and North-South direction with a heavier traffic as 30 sec.
  • The time of red light in
    East-West direction equals to the time of “green light + green light flashing +
    yellow light” in North-south direction, and vice versa.
  • When yellow light is ON,
    cars and pedestrians should not cross the road, and yellow light will last for
    5 sec for the crossing cars and pedestrians to pass safely.
     

 

·      
Timing
diagram of traffic lights in East-West direction:

 

Timing
diagram of traffic lights in North-South direction:

 

Devices:
Device
Function
X0
Start button
X1
Stop button
T0
60 sec timer. Time base: 100ms
T1
20 sec timer. Time base: 100ms
T2
5 sec timer. Time base: 100ms
T10
50 sec timer. Time base: 100ms
T11
5 sec timer. Time base: 100ms
T12
5 sec timer. Time base: 100ms
T13
30 sec timer. Time base: 100ms
S0
Initial step
S10 ~ S13
Controlling the Traffic lights in East-West direction
S20 ~ S23
Controlling the Traffic lights in North-South direction
Y0
Red light in East-West direction
Y1
Green light in East-West direction
Y2
Yellow light in East-West direction
Y10
Red light in North-South direction
Y11
Green light in North-South direction
Y12
Yellow light in North-South direction
 Ladder Program for Traffic Light Control:
 

 

 
  Program Description:
  • When
    Start is pressed, X0 = ON. PLS instruction will be executed, and M0 will create
    a rising-edge pulse to set T0. The program will enter the step ladder process.
  • ·  When Stop is pressed, X1 = ON. PLS
    instruction will be executed, and M1 will create a rising-edge pulse to execute
    [ZRST S0 S127] instruction. All steps will be reset and all traffic lights will be OFF.
  • This example is designed by
    the application of the simultaneous divergence sequence. The two sequences
    running simultaneously are East-West direction and North-South direction.
  • When the red light of
    East-West direction is ON, the corresponding state of North-South direction
    will be the sequence of “Green ON”, “Green Flashing” and “Yellow ON.”
  •  When the East-West
    direction sequence is finished (the yellow light is OFF), the 
    North-South direction sequence will be finished as well (the red light is OFF).
    The program will return to the initial step S0. 
  • When a step is transferred
    from one sequence to another sequence, the former sequence will be reset
    including the step and output point Y.
  • The time of yellow light in
    East-West direction (Y2) is not controlled by a timer because when the red
    light in North-South direction is OFF, the yellow light in North-South
    direction will be reset at the same time. In this case, T13 is ON to redirect
    the program to initial step S0, and the outputs (Y2 and Y10) corresponding to
    S13 and S23 will thus be reset.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Leave a Comment